Fire doors

Certified fire door assembly installed as part of a building fire safety system
Tested Performance Complete passive fire protection door assembly
Functional Overview

Fire Door Functional Overview

A fire door is a passive fire protection system designed to contain fire, restrict smoke movement, and support safe compartmentalisation within a building.

For effective performance, the full assembly must work together — including the frame, door leaf, hardware, glazing, and seals.

Stability
Integrity
Insulation
Smoke Control

Where are fire doors typically used?

  • Staircases, plant rooms & utility areas Commonly used at staircase access points from corridors, and for laboratories, workshops, storerooms, and plant rooms.
  • Protected escape & circulation routes Installed in circulation areas forming part of escape routes, including entrance lobbies and doors leading to external paths.
  • High-risk accommodation zones Used where corridors must remain protected from adjoining rooms, particularly in bedrooms and office dead-end conditions.
4 Core performance requirements
1 Complete tested assembly
Essential For safer evacuation routes

Andro HMPS PCGI 120minute FRD

Our fire doors are tested as per IS3614 – 2021 and IS/ISO3008-1. The frames are made of 1.2mm GI sheet. The profile of frame is 115mm * 57mm. The shutter made of 0.8mm GI sheet with finished shutter thickness of 47mm.

Door Specifications

Maximum size of the door
2300mm × 2700mm
Frame Profile
115mm × 57mm
Frame Sheet Thickness
1.2mm
Shutter Thickness
47mm
Shutter Sheet Thickness
0.8mm
Detailed view of door installation
Technical Diagram

Steel Door Frame Components

3D Exploded view of steel door frame components and hardware
1
Steel Door Frame
2
Ball Bearing Hinge
3
Hinge Reinforcement (Welded to Frame)
4
Mortar Guard For Hinge (Welded to Frame)
5
Frame Support (Welded to Frame)
6
Anchor Expansion Bolt
8
Door Silencer
9
Strike Plate for Lock
10
Strike Plate Reinforcement
11
Mortar Guard For Strike Plate (Welded to Frame)
17
Rubber Plug

Standard andro shutter profiles

Technical diagram of Andro shutter profile dimensions
Cross-section diagram of Andro shutter assembly components
Safety & Compliance

Fire Rated frame profiles

Technical diagram of Fire Rated frame profiles
Annexure 2

Standard Andro Accessories Selection

Perimeter Seal

  • Smoke Seal
  • Acoustic Seal
  • Fire & Smoke Seal

Door Bottom Seal

  • Auto Door Bottom Seal
  • Acoustic Seal
  • Fire & Smoke Seal

Locks

  • Dead Lock
  • Latch Lock
  • Sash Lock
  • Cylindrical Knob Lock

Hinges

  • 100×75×3 Double BB Hinges
  • Pin Hinges
Finishes

Standard Colours

RAL 3020
Traffic Red
RAL 9010
Pure White
RAL 8017
Chocolate Brown
RAL 9001
Cream
RAL 8003
Clay Brown
RAL 7040
Window Grey
RAL 7035
Light Grey
RAL 6005
Moss Green
RAL 5023
Distant Blue
RAL 5015
Sky Blue
RAL 9016
Traffic White
RAL 1013
Oyster White
Fire Safety Application

Emergency Exit Doors for Terrace

A reliable emergency exit solution for terrace access areas, designed to support safe evacuation, panic exit operation and smoke release through integrated louvers.

Designed for emergencies

Safe Exit When Every Second Counts

The complete door system supports fast evacuation and improves terrace access safety in residential, commercial and industrial buildings.

Safe Evacuation Route

Provides a dedicated exit point between the staircase and terrace during an emergency.

01

Smoke Release Louvers

Integrated louvers allow smoke from the stairwell to escape through the terrace area.

02

Panic Exit Bar

The push-bar mechanism allows fast and simple door opening during emergency evacuation.

03

Safety Applications

Suitable for residential towers, commercial properties and industrial buildings.

04
Product Demonstration

See the Emergency Door in Operation

Watch the door movement, panic exit operation, locking system and hardware details through the client-provided videos.

05 Demonstration Videos
01 / 05
Now Playing

Emergency Door Overview

Full view of the terrace emergency exit door, louvers and installed hardware.

Applications

Suitable Building Areas

  • Staircase-to-terrace exits
  • High-rise residential buildings
  • Commercial complexes
  • Industrial facilities
Door System

Complete Door Assembly

  • Engineered steel door frame
  • Door leaf with integrated louvers
  • Panic exit device
  • Required hardware and accessories
Product Videos

Watch the Door in Operation

View five practical demonstrations covering door movement, panic operation and hardware.

Watch Demonstrations

Our Esteemed Clientele

Trusted by Industry Leaders Across India

Technical Support

Expert Knowledge Base

Direct answers regarding installation, compliance, and engineering properties.

Absolutely. Our doors are strictly tested and certified under IS 3614-2021 and IS/ISO 3008-1. They meet the mandatory fire safety requirements for high-rise buildings, hospitals, and industrial zones across India. Authentic certificates are provided immediately upon project handover.

Yes, we specialize in bespoke manufacturing. While our standard tested max size is 2300mm x 2700mm, we utilize advanced CNC fabrication to create custom dimensions that fit specific rough openings perfectly. Note that dimensions significantly exceeding tested standards may require a special technical assessment.

HMPS doors offer superior longevity and structural integrity. Unlike wood, steel does not warp, crack, or swell due to moisture or seasonal humidity changes. They are inherently termite-proof, impact-resistant, and require virtually zero structural maintenance over their 20+ year lifespan.

Yes. The Andro system is available as a complete "plug-and-play" assembly. We can pre-fit or supply compatible ironmongery including Panic Bars, Door Closers, Mortise Locks, and Vision Panels. Using our factory-approved hardware ensures the fire rating certification remains valid.

Our automated manufacturing line allows for rapid turnaround. Standard sizes are typically dispatched within 10-14 days. Custom powder-coating colors or non-standard engineering requirements generally require 3-4 weeks. We prioritize urgent safety requirements whenever possible.